Use an Incremental encoder cable with an absolute encoder by adding JZSP-CSP12-E
Topic Description

 JZSP-CSP12-E is an add-on option cable that connects in line with an existing incremental cable allowing the incremental encoder cable to run an motor with an absoute encoder.

 JZSP-CSP12-E extends the existing cable system by 0.3 meters and will work with all Sigma 2 series motors and newer.

 


Resolution

JZSP-CSP12-E shown below:

Important Notes:

This cable is similar to the Relay Encoder extension cable but is shorter. (The Relay Encoder extension cable also has larger wire size).

Multiple batteries in the encoder system (including into CN1 BAT+/- terminals) should not be used as it would introduce another source of power and possibly damage the encoder.


Related Documents
Clearing an A.810 or A.81 Alarm when Using an Absolute Encoder in Incremental Mode
Resetting an A.810 Alarm

Product Types
SGAGS, SGDS, SGD7S Analog, SGDV, SGD7S EtherCAT, SGD7S Mechatrolink-III, SGLC, SGLFW with Sigma-5, Sigma-7Siec - Servopack, SGLGW with Sigma-5, SGD7W EtherCAT, SGLTW with Sigma-5, SGD7W Mechatrolink-III, SGLF2, SGLFW with Sigma-7, SGMAV, SGLGW with Sigma-7, SGMCS with Sigma-5, SGMCV with Sigma-5, SGLTW with Sigma-7, SGM7A, SGMGV, SGM7D, SGMJV, SGM7E Direct Drive, SGM7F, SGMMV, SGM7G, SGMSV, SGMVV, SGM7J, SGM7P, SGT1F, SGMCS with Sigma-7, SGTMF, SGTMM, SGMCV with Sigma-7, Sigma-5-SD, S7G, SigmaLogic, S7A, S7P, SGDV Mini, S7J, SigmaLogic7 Compact, SigmaLogic7 Modbus, SGD7S EtherCAT with FSoE,
All Applications
Advanced Random Rotary Knife with Cam Blend, Air Compressor, Blister pack Thermoformer, Cartoner, Centrifuge, Conveyor, Crane/Hoist, Dynamometer, Elevators and Escalators, Extrusion, Fans/Blowers, Feed To Length, General Machinery, HVAC, Irrigation, Labeler, Laundry, Linear Flying Shear, Machine Tool, Mixer, Other, Packaging, Palletizer, Precision Grinding, Pump, Punch Press, Rotary Knife, Rotary Placer, Rotary Table Indexer, Screw Feeder, Synch-Belt, Textile, Winding,